opensofts.org

Home > View Server Exe Error > View_server.exe Error Unable To Get Cleartext For Vob

View_server.exe Error Unable To Get Cleartext For Vob

Program:C:\PROGRA~1\RATIONAL\CLEARQ~1.0\CQINTS~2.EXE R6025 - pure virtual function call rcptcp_create: RPC: Remote system error - [WINSOCK] Connection refused clearlicense: Error: unable to contact albd_server on host 'hostname' NPLogon /xdr/albd: Error: Unable to contact So if for example the directory permissions were 755, the only user who could checkout files in the directory would be the directory owner (as the owner is granted write permissions). The actual install location is arbitrary. cleartool: Error: Pathname is not within a VOB: "." Any ct commands that have to do with listing or manipulating elements must be done with a view set and inside a have a peek at this web-site

As root: # cd atria-home/etc # ./atria_start stop # ./atria_start start Back to the INDEX. This registration of the user's password is unique to this user if the "Allow all users to see this installation." was used during the NFS Maestro install. The view is a snapshot view which is local to the client's desktop or laptop. cleartool: Error: Could not register gpath in the prefix map.

For inexplicable reasons, the share, not the directory itself but the share, had "Change" permissions only for the group of users that needed to create views there. Quite a challenge, it was… Helpful link: Determine if a UNIX or Linux application is 32-bit or 64-bit Share this:TwitterFacebookLike this:Like Loading... Error: "java.io.IOException: Unable to acquire lock to copy area registry. (Lock file is "path\.ccase_wvreg_lockfile". This group can either be a local user group created on the local machine or a domain group that is accessed when the user logs on.

mv: cannot rename element: Read-only file system The first occurs on Windows when attempting to rename a CC versioned file with the standard "move" command. If not already running (hclnfsd or pcnfsd will show up in the Rpcinfo tool of NFS Maestro), you need to start the daemon on the UNIX machine and ensure it will OLE exception from "ClearCase.Application.1": Unable to access "extended version path": Invalid argument. The problem is that CC doesn't know what your primary group name is.

Independent of CC, you should be able to successfully run an rsh command on the command-line. This error showed up when attempting a clearimport as a regular user on Windows client connected to a UNIX server. What OS is the server running? (Yes, I work in support. http://www-01.ibm.com/support/docview.wss?uid=swg21168360 Also, check the permissions on the parent directory and ensure that the group has read-write privileges.

You can verify this in the view properties/protections. On Windows, run atria-home/etc/utils/credmap. 3) The view has group permissions other than your PRIMARY_CLEARCASE_GROUP. Warning: VOB is unavailable This error occurs when you try to get information on an object that was attached to a VOB that was deleted in a non-standard way or is You can obtain this by adding the following to your smb.conf somewhere in the global section: debug level = 5 This is not the cleanest way to handle this, but it

The first error occurs when you attempt to create an object in a VOB in which you are not a member of one of its groups. https://adventuresinscm.wordpress.com/2012/06/17/sporadic-cleartext-errors-using-samba/ If that view will never be available again, do an rmdo on the specific DO referenced by the accompanying Warning message. You can register them via Start -> Programs -> NFS Maestro -> NFS Network Access -> Register or can register them on the command-line with "nfs register unix-login. Submit feedback to IBM Support 1-800-IBM-7378 (USA) Directory of worldwide contacts Contact Privacy Terms of use Accessibility United States English English IBM® Site map IBM IBM Support Check here to

cleartool: Error: Trouble looking up element "element" in directory "directory". http://opensofts.org/view-server-exe-error/view-server-exe-error-unknown-style-protections.php cleartool: Error: Unable to determine absolute pathname for "\vobtag" - Permission denied cleartool: Error: Unable to access "\vobtag": Input/output error. This error shows up when attempting a "ct relocate". Changing the permissions for that group to be "Full Control" solved the problem.

CRVAP0239E Error: CRVSV0078E Error from RPC server: CRVSV0841E 'Permission denied' cleartool: Error: Failed to record hostname "hostname" in storage directory "local-path-to-storage-directory". You can tell because my "answer" consists mostly of questions.) ================================================================= Brian Cowan Advisory Software Engineer ClearCase Customer Advocacy Group (CAG) Rational Software IBM Software Group 81 Hartwell Ave Lexington, MA You can either copy the file to a vob-tag area, thus creating a view-private file or perhaps if not working on an explicit file, you need to just cd to a Source When we try to perform any operation on the files present in the VOB we get the below error.

The second is an attempt to use the standard UNIX "mv" command. view needs reformat mvfs: ERROR: VIEW = view-tag VOB = vob-tag - ClearCase view error mvfs: ERROR: view=view-tag vob=vob-tag - ClearCase vob error Can't get primary GID Attempt to get location element [checkedout but removed] This is due to an element that is checked out to a view, but the view-private file either could not be written to that directory or

On Windows, run atria-home/etc/utils/credmap.

A sample entry from your log reads as follows 27/07/2009 14:26:35 view_server(3760): Warning: text_file_delta: Error: Unable to open file "\\Ngsrvhdc254\CCPMAC\PMAC.vbs\c\cdft\31\2\tmp_151624.4": Permission denied Looks like the user who is trying to access Is this the first VOB on this server? [email protected]@ [eclipsed by checkout] cleartool: Error: Can't create object with group (GID) that is not in the VOB's group list. He is currently working for LM Ericsson in Athlone, Ireland.

The solution to restoring the permissions was to run the following in the .identity directory: # chmod 2400 gid group.* # chmod 4400 uid Back to the INDEX. But I recently got this in conjunction with a clearer report in the vobrpc log (I think), for 'group not declared in the vob' (or similar). An attempt to Shutdown and Startup the albd service via the ClearCase Properties failed. have a peek here Regards Shalini _______________________________________________ cciug mailing list [email protected] Unsubscribe:[email protected] More...

Can any one of you help me in fixing this problem. This error occurred when attempting to remove a group from the groups list of a VOB as the ClearCase administrator on Windows. Related information About ClearCase Snapshot view updates Cross reference information Segment Product Component Platform Version Edition Software Development Rational ClearCase View: Snapshot Document information More support for: Rational ClearCase View: Snapshot However, for snapshot views you will get an error about an update failure and other messages.

If the attempted command looked like # ct mktag -view -tag new-view-tag viewstore/new-view-tag.vws it may be necessary to include the extended path information # ct mktag -view -tag new-view-tag -host server-name This is the result of a "ct rmdo" on an unshared DO. The first error occurs if the link is pointing to an existing element and the second if the link points to a file that is not a versioned object. If you have permission to view/modify the registry, ensure the ProtectionMode either does not exist (anyone can map a drive) or that it is set to "1" (also, anyone can map

Symptom Attempts to update a snapshot view results in the following error: cleartool: Error: Unable to load "". cleartool: Error: No permission to perform operation "checkin". If the view is common to both UNIX and the Windows client, set the view on the UNIX side and just delete the view-private file from the VOB directory. element [disputed checkout, checkedout but removed] Error: failed to load DLL ntadmin.dll: -1 ERROR: Your CWD must be the install sub-directory within the patch sub-directory of a release area.

There are various VOBs already present on the server. Somehow the system still thinks that the VOB/view is accessed through that drive letter, perhaps because it was there in the past. Error Description: timed out trying to communicate with ClearCase remote server.